AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 268 of 485
Query Format
[SOURce:]VOLTage[:AC]#:LIMIT:SATuration:MAXimum?
Description
Returns maximum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage[:AC]#:LIMIT:SATuration:RANGe? for details.
Returned Data Format
<nr2>
Query Example
VOLT:AC3:LIM:SAT:MAX?
301.154
Query Format
[SOURce:]VOLTage[:AC]#:LIMIT:SATuration:MINimum?
Description
Returns minimum sine wave RMS voltage at which saturation of the
output inverter will occur.
See [SOURce:]VOLTage[:AC]#:LIMIT:SATuration:RANGe? for details.
Returned Data Format
<nr2>
Query Example
VOLT:AC3:LIM:SAT:MIN?
0.000
Command Syntax
[SOURce:]VOLTage[:AC]:INITial
Description
This command is equivalent to the “[SOURce:]INITial <n>” command
but applies only to the AC1, AC2 and AC3 parameters.
VOLT:INIT? = ON Set points of the unit at power on will be the last set after power off.
The set points affected by this command are:
- Voltage AC1
- Voltage AC2
- Voltage AC3
VOLT:INIT? = OFF Set points of the unit at power on will have a default value of:
- Voltage AC1 = 0V
- Voltage AC2 = 0V
- Voltage AC3 = 0V
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
VOLT:AC:INIT OFF
Query Format
[SOURce:]VOLTage[:AC]:INITial?
Returned Data Format
<b>
Query Example
VOLT:AC:INIT?
0
Summary of Contents for AFX Series
Page 484: ......