AFX SERIES® OPERATION MANUAL
SECTION 13:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 461 of 485
Error Source
Code
Category Error Message
Possible Cause
Resolution
Front panel
Error
86
Error
Unable to enable output.
One or more primary
stages failed to enable.
Output ON failed due to
power input stage fault
Try recycling power. If
error persists, contact
customer service
Front panel
Error
89
Error
Digital I/O interface
conflict: Remote inhibit is
active.
Conflict between front
panel and Remote Inhibit
input level
Resolve conflict. Check
input to Remote Inhibit
Front panel
Error
90
Error
Digital I/O interface
conflict: Remote enable is
active.
Conflict between front
panel and Remote
Enable input level
Resolve conflict. Check
input to Remote Enable
Front panel
Error
91
Error
Internal error: Unknown
phase mode.
Selected Phase Mode
(FORM) is unknown
Try recycling power. If
error persists, contact
customer service
Front panel
Error
92
Error
Unable to disable output.
One or more primary
stages failed to disable.
Output OFF failed.
Attempt to disable one or
more inverter stages
failed
Turn Unit off with Circuit
Breaker
Front panel
Error
93
Error
Internal error: Cannot
configure timer.
Timer Configuration Error Reset front panel
Front panel
Error
94
Error
Internal error: Cannot
create timer.
Timer Creation Error
Reset front panel
Front panel
Error
95
Error
Digital I/Os interface
conflict: Serial interface
flow control is active.
RS232 or USB interface
error
Check RS232 or USB
settings
Front panel
Error
96
Error
Data logger storage error. Error saving
measurement data to
selecting memory device.
Memory device may have
been removed
Check for Memory device
presence
Front panel
Error
97
Error
Output enable in
progress.
Waiting to turn output
off. Changing from
Output ON to Output OFF
state
Wait for power stages
and inverters to fully
engage
Front panel
Error
98
Error
DC Voltage not allowed in
"AC mode".
Setting conflict. Setting
does not match mode
Check setting
Front panel
Error
99
Error
AC Voltage not allowed in
"DC mode".
Setting conflict. Setting
does not match mode
Check setting
Front panel
Error
100
Error
DC voltage set point
cannot change due to
user limit.
Setting conflict. Setting
outside of User Limits
Check setting
Front panel
Error
101
Error
AC voltage set point
cannot change due to
user limit.
Setting conflict. Setting
outside of User Limits
Check setting
Front panel
Error
102
Error
DC voltage set point
cannot change due to low
range.
Setting conflict. Setting
outside of User Limits
Check setting
Front panel
Error
103
Error
AC voltage set point
cannot change due to low
range.
Setting conflict. Setting
outside of User Limits
Check setting
Front panel
Error
104
Error
Waveform change in
progress.
Waveform change in
progress
Wait
Front panel
Error
105
Error
Error changing service
name
Internal Service Error.
Could not change service
Try recycling power. If
error persists, contact
customer service
Front panel
Error
106
Error
Error getting service
name
Internal Service Error.
Could not get service
name
Try recycling power. If
error persists, contact
customer service
Summary of Contents for AFX Series
Page 484: ......