AFX SERIES® OPERATION MANUAL
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 138 of 485
SOFT KEY
Description
Debug Mode (SK4)
Displays the Debug Execution mode screen. See section 6.6.4
Run Screen (SK5)
Returns to the regular TRANSIENT PROGRAM screen used for
transient execution mode. See section 6.6.4.
Table 6-11: Available TRANSIENT EDIT screen soft keys
Once created, a transient sequence can be saved as part of the instrument setup. Refer to
Section 6.7.4 for information on saving and recalling setups.
6.6.4
LIST Transient Execution Modes
Transients can be executed as soon as they have been entered. To execute a transient, the
output
must be ON
. Sometimes it is best to debug a new transient sequence to make sure it
performs the intended test and all values were entered correctly. To do so, the DEBUG
mode is provided.
DEBUG MODE
The debug mode can be selected from the TRANSIENT VIEW screen by pressing the “Debug
Mode” soft key (SK4). This changes the TRANSIENT VIEW screen from EDIT to DEBUG mode
and displays a different set of soft keys to control execution.
Figure 6-15: TRANSIENT Debug mode screen
The following execution control soft keys are available.
SOFT KEY
Description
Run (SK1)
Starts the transient from the currently selected row number
Step (SK2)
Single steps one row at a time
Step Mode (SK3)
Executes one step at a time
Edit Mode (SK4)
Stops execution and reverts to Edit mode
Run Screen (SK5)
Returns to the regular TRANSIENT PROGRAM screen used for
transient execution mode. See section 6.6.4.
Table 6-12: Available TRANSIENT DEBUG screen soft keys
Note:
The progress of the transient is indicated by the “Program” status bar at the bottom
of the screen.
Summary of Contents for AFX Series
Page 484: ......