Command Syntax
[SOURce:]PROTect:PEAK:CURRent:LEVel <LEVEL>
Description
This command sets the peak current protection level.
Parameters
< LEVEL >
Parameter Format
<nr2>
Example
PROT:PEAK:CURR:LEV 95.0
Query Format
[SOURce:]PROTect:PEAK:CURRent:LEVel?
Returned Data Format
<b>
Query Example
PROT:PEAK:CURR:LEV?
95.0000
Query Syntax
[SOURce:]PROTect:PEAK:CURRent:LEVel:MAXIMUM?
Description
This query command returns the maximum allowable setting for the
peak current protection level.
Returned Data Format
<nr2>
Query Example
PROT:PEAK:CURR:LEV:MAX?
104.0000
Query Syntax
[SOURce:]PROTect:PEAK:CURRent:LEVel:MINIMUM?
Description
This query command returns the minimum allowable setting for the
peak current protection level.
Returned Data Format
<nr2>
Query Example
PROT:PEAK:CURR:LEV:MIN?
104.0000
Query Syntax
[SOURce:]PROTect:PEAK:CURRent:LEVel:DEFault?
Description
This query command returns the default setting for the peak current
protection level.
Returned Data Format
<nr2>
Query Example
PROT:PEAK:CURR:LEV:DEF?
104.0000
Query Syntax
[SOURce:]PROTect:PEAK:CURRent:TRIPped?
Description
This query command returns tripped state of the peak current
protection level funtion. Return 1 if tripped, 0 if not.
Returned Data Format
<b>
Query Example
PROT:PEAK:CURR:TRIP?
1
Command Syntax
[SOURce:]PROTect:PEAK:CURRent:TRIPped:CLEar
Description
This command clears the the peak current protection protection
tripped status.
Parameters
None
Parameter Format
n/a
Example
PROT:PEAK:CURR:TRIP:CLE
Summary of Contents for AFX Series