Command Syntax
[SOURce:]INTHarmonic:STATe <b>
Description
This command enables (1) or disables Inter Harmonics mode. When
off, no interharmonics are generated. This command can only be sent
while the OUTPUT is OFF. If the OUTPUT is ON, an error is generated
and no change of state occurs. (“Unable to execute this action with
output enabled”).
Parameters
< 0 | OFF | 1 | ON >
Parameter Format
<b>
Example
INTH:STAT ON
Query Format
[SOURce:]INTHarmonic:STATe?
Description
Query format returns the interharmonic state setting.
Returned Data Format
<b>
Query Example
INTH:STAT?
1