AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 369 of 485
Command Syntax
SYSTem:AIO:OUTput[n]:GAIN <nr2>
Description
Sets the full-scale gain of the AFX measurement mapped to the
analog input.
Parameters
Full scale value
Parameter Format
<nr2>
Example
SYST:AIO:OUT1:GAIN 230.0
Query Format
SYSTem:AIO:OUTput[n]:GAIN?
Returned Data Format
<nr2>
Query Example
SYST:AIO:OUT1:GAIN?
425.0000
Query Format
SYSTem:AIO:OUTput[n]:GAIN:DEFault?
Description
Returns the default full-scale gain for the specified analog output
port.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:OUT1:GAIN:DEF?
425.0000
Query Format
SYSTem:AIO:OUTput[n]:GAIN:MAXimum?
Description
Returns the maximum gain for the specified analog output port.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:OUT1:GAIN:MAX?
100000.00000
Query Format
SYSTem:AIO:OUTput[n]:GAIN:MINimum?
Description
Returns the minimum gain for the specified analog output port.
Parameters
None
Returned Data Format
n/a
Query Example
SYST:AIO:OUT1:GAIN:MIN?
-100000.00000
Command Syntax
SYSTem:AIO:OUTput[n]:OFFSET <nr2>
Description
Sets the offset of the specified analog output port.
Parameters
Offset
Parameter Format
<nr2>
Example
SYST:AIO:OUT1:OFFSET 50.0
Query Format
SYSTem:AIO:OUTput[n]:OFFSET?
Returned Data Format
<nr2>
Query Example
SYST:AIO:OUT1:OFFSET?
50.00
Summary of Contents for AFX Series