AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 333 of 485
Command Syntax
[SOURce:]INTHarmonic:VOLTage[:AC#]
Description
Sets the inter harmonic voltage amplitude for the selected phase (1 =
A, 2 = B, 3 = C) or for all three phases if the phase selection is omitted
in Vac RMS
Parameters
Voltage
Parameter Format
<nr2>
Example
INTH:VOLT:AC1 12.00
Query Format
[SOURce:]INTHarmonic:VOLTage[:AC#]?
Description
Query format returns the interharmonic amplitude setting.
Returned Data Format
<nr2>
Query Example
INTH:VOLT?
12.0000, 0.0000, 0.0000
Command Syntax
[SOURce:]INTHarmonic:VOLTage:AC#:DEFault
Description
Sets the default amplitude of the interharmonic voltage component
for all phases. The factory default setting is 0.000 Vrms.
Parameters
Frequency
Parameter Format
<nr2>
Example
INTH:VOLT:AC:DEF 5
Query Format
[SOURce:]INTHarmonic:VOLTage:AC#:DEFault?
Description
Query format returns the interharmonic default amplitude setting.
Returned Data Format
<nr2>
Query Example
INTH:VOLT:AC:DEF?
5.0000, 5.0000, 5.0000
Query Format
[SOURce:]INTHarmonic:VOLTage:AC#:MAXimum?
Description
Returns the maximum value for the interharmonic amplitude setting
which is 300.0000 Vac RMS.
Returned Data Format
<nr2>
Query Example
INTH:VOLT:AC:MAX?
300.0000
Query Format
[SOURce:]INTHarmonic:VOLTage:AC#:MINimum?
Description
Returns the minimum value for the interharmonic amplitude setting
which is 0.0000 Vac RMS.
Returned Data Format
<nr2>
Query Example
INTH:VOLT:AC:MIN?
0.0000
Summary of Contents for AFX Series