8.10.4
AUX I/O Calibration Commands
SYSTem:AIO
:INPut#
:CALibration
:GAIN{?]
:DEFault[?]
:MAXimum
:MINinimum
:OFFset{?]
:DEFault[?]
:MAXimum
:MINinimum
:OUTput#
:CALibration
:GAIN{?]
:DEFault[?]
:MAXimum
:MINinimum
:OFFset{?]
:DEFault[?]
:MAXimum
:MINinimum
8.10.4.1
SYSTem:AIO:INPUT#:CALibration
Command Syntax
SYSTem:AIO:INput[n]:CALibration:GAIN <nr2>
Description
Calibrates the full scale gain of the AFX parameter controlled
by the analog input.
Parameters
Reference
Parameter Format
<nr2>
Example
SYST:AIO:IN1:CAL:GAIN 100.0
Query Format
SYSTem:AIO:INput[n]:CALibration:GAIN?
Returns calibration coefficient
Returned Data Format <nr2>
Query Example
SYST:AIO:IN1:CAL:GAIN?
1.000
Query Command
SYSTem:AIO:INput[n]:CALibration:GAIN:DEFault?
Returns default calibration coefficient value
Returned Data Format <nr2>
Query Example
SYST:AIO:IN1:CAL:GAIN:DEF?
1.000
Query Command
SYSTem:AIO:INput[n]:CALibration:GAIN:MAXimum?
Returns upper limit of calibration coefficient value
Returned Data Format <nr2>
Query Example
SYST:AIO:IN1:CAL:GAIN:MAX?
1.000