AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 246 of 485
Command Syntax
PROGram:EXECuted:INFOrmation <cr> [,<nr1>] [,<cr>]
Description
This command assigns program information data to the executing
program.
Parameters
Information string <cr>
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Parameter Format
<cr> [,<nr1>] [,<cr>]
Example
PROG:EXEC:INFO 3, INTERNAL, SAMPLE TEST
Query Format
PROGram:EXECuted:INFOrmation? [,<nr1>] [,<cr>]
Returned Data Format
<cr>
Query Example
PROG:EXEC:INFO? 2, USB
-> Program info string
Command Syntax
PROGram[:SELected]:ALIAS <cr> [,<nr1>] [,<cr>]
Description
This command assigns a user provided alias string name to the
selected program. Program number and memory type are optional
parameters.
Parameters
Alias String <cr>
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Parameter Format
<cr> [,<nr1>] [,<cr>]
Example
PROG:ALIAS TEST1
Query Format
PROGram[:SELected]:ALIAS? [,<nr1>] [,<cr>]
Returned Data Format
<cr>
Query Example
PROG:ALIAS?
TEST1
Command Syntax
PROGram:EXECuted:ALIAS <cr> [,<nr1>] [,<cr>]
Description
This command assigns a user provided alias string name to the
executing program. Program number and memory type are optional
parameters.
Parameters
Alias String <cr>
Option: PROGRAM NUMBER [,<nr1>]
Option: MEMORY [,<cr>]– Available are: INTERNAL | RAM | USB
Parameter Format
<cr> [,<nr1>] [,<cr>]
Example
PROG:EXEC:ALIAS TEST2
Query Format
PROGram:EXECuted:ALIAS? [,<nr1>] [,<cr>]
Returned Data Format
<cr>
Query Example
PROG:EXEC:ALIAS?
TEST2
Summary of Contents for AFX Series
Page 484: ......