AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 289 of 485
Command Syntax
[SOURce:]PROTect[:RMS]:CURRent:TDELAY <DELAY>
Description
This command sets the rms current protection trip delay in 100
msecs increments, i.e. as setting of 5 means 500 msec.
Parameters
< DELAY >
Parameter Format
<nr1>
Example
PROTect:CURR:TDELAY 5
Query Format
[SOURce:]PROTect[:RMS]:CURRent:TDELAY?
Returned Data Format
<nr1>
Query Example
PROT:CURR:LEV?
5
Query Syntax
[SOURce:]PROTect[:RMS]:CURRent:TDELAY:MINimum?
Description
This command returns the minimum rms current protection trip
delay setting.
Query Example
PROT:CURR:TDELAY:MIN?
0
Query Syntax
[SOURce:]PROTect[:RMS]:CURRent:TDELAY:MAXimum?
Description
This command returns the maximum rms current protection trip
delay setting.
Query Example
PROT:CURR:TDELAY:MAX?
3000
Query Syntax
[SOURce:]PROTect[:RMS]:CURRent:TDELAY:DEFault?
Description
This command returns the default rms current protection trip delay
setting.
Query Example
[SOURce:]PROTect[:RMS]:CURRent:TDELAY:DEFault?
41.667
Query Syntax
[SOURce:]PROTect[:RMS]:CURRent:TRIPped?
Description
This command returns rms current protection trip status. Returns 1 if
tripped or 0 if not.
Query Example
PROT:CURR:TRIP?
41.667
Command Syntax
[SOURce:]PROTect[:RMS]:CURRent:TRIPped:CLEar
Description
This command clears the rms current protection trip status. Once
cleared, the power source output can be enabled.
Parameters
None
Parameter Format
n/a
Example
PROT:CURR:TRIP:CLE
Summary of Contents for AFX Series