AFX SERIES® OPERATION MANUAL
SECTION 8:
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 332 of 485
8.7.13
IEC413 Option Interharmonics Commands
The following SCPI commands apply only to AFX models with the -413 Option installed. The
presence of this option can be checked using the *IDN? Query to check for the letter “C” in the AXF
Model number. Examples: 3150AFX-4AG
C
”. See section 4.16 on page 48 for more details.
Command Syntax
[SOURce:]INTHarmonic:FREQuency
Description
Sets the frequency of the interharmonic voltage component for all
phases. The query format returns the active setting
Parameters
Frequency
Parameter Format
<nr2>
Example
INTH:FREQ 470
Query Format
[SOURce:]INTHarmonic:FREQuency?
Description
Query format returns theinterharmonic frequency setting.
Returned Data Format
<nr2>
Query Example
INTH:FREQ?
470.0000
Command Syntax
[SOURce:]INTHarmonic:FREQuency:DEFault
Description
Sets the default frequency of theinter harmonic voltage component
for all phases. The factory default setting is 1800 Hz.
Parameters
Frequency
Parameter Format
<nr2>
Example
INTH:FREQ:DEF 90
Query Format
[SOURce:]INTHarmonic:FREQuency:DEFault?
Description
Query format returns the interharmonic frequency setting.
Returned Data Format
<nr2>
Query Example
INTH:FREQ:DEF?
90.0000
Query Format
[SOURce:]INTHarmonic:FREQuency:MAXimum?
Description
Returns the maximum value for the interharmonic frequency setting
which is 10,000 Hz..
Returned Data Format
<nr2>
Query Example
INTH:FREQ:MAX?
10000.0000
Query Format
[SOURce:]INTHarmonic:FREQuency:MINimum?
Description
Returns the minimum value for the interharmonic frequency setting
which is 15 Hz..
Returned Data Format
<nr2>
Query Example
INTH:FREQ:MIN?
15.0000
Summary of Contents for AFX Series
Page 484: ......