4.16
IEC413 Option
This option ads inter harmonic generation to an AFX Master unit. Models with this option have the
letter “C” in the model number desgination immediately following the –“AG” part. For example,
3150AFX-4AG
C
E.
This option removed to user programmable featurs from the standard AFX feature set:
•
User programmable output OVP level. The OVP level is fixed at the maximum allowable
setting.
•
User programmable Peak output current protection. The peak level is fixed at the maximum
level.
Note:
Disabling of these features does not affect reliability of the power source.
Interharmonics control is available through SCPI bus commands only. No front panel user interface
is included with this option.
This interharmonic waveform generator may be used to support IEC61000-4-13 harmonics and
interharmonics immunity testing of an EUT. The IEC413 Test Sequence suite for PPSC Test Manager
Windows 10 software is included with this option. This test sequence handles all harmonics and
interhamonics frequency steps and amplitudes programming.
Technical Specifications:
IEC413 Option
Frequency Range
15.00 Hz to 10,000 Hz
Amplitude Range
0.00 Vac to 300.00 Vac
Phase Angle Programming
0.0° to 359.9° with respect to Phase fundamental
Available on Models
3xxxAFX-2AGC or 3xxxAFX-4AGC models only