Command Syntax
MEASure:LOGger:FILELimit <nr1>
Description
Sets the limit of samples to save in the file. If the limit is reached and
the logging process continues, a new file will be created.
Parameters
Limit in number of samples.
Parameter Format
<nr1>
Example
MEAS:LOG:FILEL 100
Query Format
MEASure:LOGger:FILELimit?
Returned Data Format
<nr1>
Query Example
MEAS:LOG:FILEL?
10000
Command Syntax
MEASure:LOGger:FILEName <cr>
Description
Sets the data logging file name
Parameters
Filename between double quotes
Parameter Format
<cr>
Example
MEAS:LOG:FILEN “Measurement-AC+DC”
Query Format
MEASure:LOGger:FILEName?
Returned Data Format
<cr>
Query Example
MEAS:LOG:FILEN?
Measurement-AC+DC
Command Syntax
MEASure:LOGger:MEMory <cr>
Description
Select the memory where the logging files will be saved. By default it
is RAM unless a memory stick or USB drive was inserted and selected
with this command:
MEAS:LOG:MEM:CAT? can be used to get the available memories.
Parameters
Memory name between double quotes.
Parameter Format
<cr>
Example
MEAS:LOG:MEM “USBA”
Query Format
MEASure:LOGger:MEMory?
Returned Data Format
<cr>
Query Example
MEAS:LOG:MEM?
USBA
Query Format
MEASure:LOGger:MEMory:CATalog?
Description
Returns the catalog of available memory names.
Returned Data Format
<cr>
Query Example
MEAS:LOG:MEM:CAT?
RAM, USBA