AFX SERIES® OPERATION MANUAL
Rear Panel, Connectors and Protection
Entire Contents Copyright
2018 by Pacific Power Source, Inc. (PPS) • All Rights Reserved • No reproduction without written authorization from PPS.
AFX Series Power Source Operation Manual
Page 187 of 485
7.2
External Voltage Sense Input Terminals
WARNING
HAZARDOUS OUTPUT: The power source output may be set to hazardous voltage levels. It
provides basic isolation from the ac input mains. Therefore, the external voltage sense must also
always be considered hazardous. Connections must be inaccessible to operator in all situations
when ac input mains voltage is applied.
Always disconnect power supply from the mains before connecting or disconnecting to the
hazardous external voltage sense terminals.
AVERTISSEMENT
SORTIE DANGEREUSE: La sortie de l´appareil peut être réglée à des niveaux de tension dangereux.
L´appareil fournit une isolation de base du réseau d'entrée AC. Par conséquent, la sortie doit
toujours être considérée comme dangereuse. Les connexions doivent être inaccessibles à
l'opérateur dans toutes les situations où la tension d´entrée secteur est appliquée.
Toujours débrancher l'alimentation secteur avant de connecter ou déconnecter les bornes de
sortie dangereuses.
This section covers external voltage sensing. This feature improves voltage accuracy at the
point of load when used correctly.
Note:
External Voltage sense is sometimes referred to as Remote Voltage sense and
Internal Voltage sense is sometimes referred to as Local Voltage sense. Both
definitions are used in the industry. For consistency, External Voltage Sense and
Internal Voltage Sense are used in this manual.