Bit A39615 is turned ON when the programs do not match.
3-6-23 Power Supply Unit OFF/Error Flags
Bit A39700 is turned ON when the right Power Supply Unit in the CPU Rack is
OFF or its start input terminals are open.
Bit A39701 is turned ON when the left Power Supply Unit in the CPU Rack is OFF
or its start input terminals are open.
Bit A39800 is turned ON when there is an error in the right Power Supply Unit in
the CPU Rack. Bit A39801 is turned ON when there is an error in the left Power
Supply Unit in the CPU Rack.
Bit A39802 is turned ON when there is an error in the right Power Supply Unit in
the Expansion CPU Rack or Expansion I/O Rack #1.
Bit A39803 is turned ON when there is an error in the left Power Supply Unit in
the Expansion CPU Rack or Expansion I/O Rack #1.
Bits A39804 through A39815 contain the Error Flags for Power Supply Units in
Expansion I/O Racks #2 through #7, as shown in the following table.
Bit
Function
A39804
Expansion I/O Rack #2 Right Power Supply Unit Error Flag
A39805
Expansion I/O Rack #2 Left Power Supply Unit Error Flag
A39806
Expansion I/O Rack #3 Right Power Supply Unit Error Flag
A39807
Expansion I/O Rack #3 Left Power Supply Unit Error Flag
A39808
Expansion I/O Rack #4 Right Power Supply Unit Error Flag
A39809
Expansion I/O Rack #4 Left Power Supply Unit Error Flag
A39810
Expansion I/O Rack #5 Right Power Supply Unit Error Flag
A39811
Expansion I/O Rack #5 Left Power Supply Unit Error Flag
A39812
Expansion I/O Rack #6 Right Power Supply Unit Error Flag
A39813
Expansion I/O Rack #6 Left Power Supply Unit Error Flag
A39814
Expansion I/O Rack #7 Right Power Supply Unit Error Flag
A39815
Expansion I/O Rack #7 Left Power Supply Unit Error Flag
3-6-24 Online I/O Replacement Flags
A399
00 to 07
Slot Undergoing Online I/O Replacement (2-digit BCD)
08 to 11
Rack Undergoing Online I/O Replacement (1-digit
BCD)
12 to 13
Not used.
14
Online I/O Replacement Status Retention Bit
15
Online I/O Replacement In Progress Flag
Bit A39900 to A39911 indicate the rack number and slot number of the Unit un-
dergoing online I/O replacement. Bits 08 to 11 contain the rack number (1-digit
BCD) and bits 00 to 07 contain the slot number (2-digit BCD).
Bit A39914 indicates whether the status of data in I/O Units will be retained while
the rack is undergoing online I/O replacement. Bit A39914 is turned ON if the
status of the I/O bits is retained and turned OFF if the bits are cleared.
Bit A39915 is turned ON during online I/O replacement.
Duplex Program Mismatch
Flag (A39614)
CPU Rack PSU OFF Flags
(A39700 and A39701)
CPU Rack PSU Error Flags
(A39800 and A39801)
Rack #1 PSU Error Flags
(A39802 and A39803)
PSU Error Flags for Racks
#2 through #7
(A39804 to A39815)
Unit Undergoing Online I/O
Replacement
Online I/O Replacement
Status Retention Flag
(A39914)
Online I/O Replacement In
Progress Flag (A39915)
Auxiliary Area
Section 3-6