![Omron CVM1D Operation Manual Download Page 302](http://html1.mh-extra.com/html/omron/cvm1d/cvm1d_operation-manual_742532302.webp)
297
5-21-16 TANGENT TO ANGLE: ATAN(465)
(465)
ATAN
S
R
Ladder Symbol
Variations
↑
ATAN(465)
Operand Data Areas
S: First source word
CIO, G, A, T, C, #, DM
R: First result word
CIO, G, A, DM
When the execution condition OFF, ATAN(465) is not executed. When the
execution condition is ON, ATAN(465) computes the angle (in radians) for a tan-
gent expressed as the 32-floating-point content of S and S+1, and places the
result in R and R+1.
R+1
R
S
Source (floating-point data, 32 bits)
S+1
Result (floating-point data, 32 bits)
TAN
–1
The result is output to words R+1 and R as an angle (in radians) within the range
of –
π
/2 to
π
/2.
Relation Between Input Data and Result
S: Input data (tangent)
R: Result (radians)
R
Precautions
The tangent must be floating-point data within a range of –1.0 to 1.0.
Note Refer to page 101 for general precautions on operand data areas.
Flags
ER (A50003):
The tangent is not within the range of –1.0 to 1.0.
The tangent is not floating-point data.
The content of a
*
DM word is not BCD when set for BCD.
EQ (A50006):
The exponent and mantissa of the result are 0.
N (A50008):
The result is a negative number.
OF (A50009):
OFF when the computation is executed.
UF (A50010):
OFF when the computation is executed.