![Omron CVM1D Operation Manual Download Page 303](http://html1.mh-extra.com/html/omron/cvm1d/cvm1d_operation-manual_742532303.webp)
298
5-21-17 SQUARE ROOT: SQRT(466)
(466)
SQRT
S
R
Ladder Symbol
Variations
↑
SQRT(466)
Operand Data Areas
S: First source word
CIO, G, A, T, C, #, DM
R: First result word
CIO, G, A, DM
When the execution condition OFF, SQRT(466) is not executed. When the
execution condition is ON, SQRT(466) computes the square root of the 32-float-
ing-point content of S and S+1, and places the result in R and R+1.
R+1
R
S
Source (floating-point data, 32 bits)
S+1
Result (square root, floating-point data, 32 bits)
If the absolute value of the result is greater than the maximum value that can be
expressed for floating-point data, the Overflow Flag (A50009) will turn ON and
the result will be output as
±
R
.
Relation Between Input Data and Result
R
S: Input data
R: Result
Precautions
S and S+1must be non-negative floating-point data.
Note Refer to page 101 for general precautions on operand data areas.
Flags
ER (A50003):
S and S+1is a negative number.
S and S+1is not floating-point data.
The content of a
*
DM word is not BCD when set for BCD.
EQ (A50006):
The exponent and mantissa of the result are 0.
N (A50008):
OFF when the computation is executed.
OF (A50009):
The absolute value of the result is greater than the maximum
value that can be expressed for floating-point data.
UF (A50010):
OFF when the computation is executed.
Description