The program is set up so that a rotary encoder (000000) controls execution of
SFT(050) through a DIFU(013), the rotary encoder is set up to turn ON and OFF
each time a product passes the first sensor. Another sensor (000002) is used to
detect faulty products in the chute so that the pusher output and bit 120003 of the
shift register can be reset as required.
Sensor
Chute
(00002)
(00500)
Sensor
(00001)
Rotary Encoder
(00000)
Pusher
(050)
SFT
1200
1201
00000
LD
000001
00001
LD
000000
00002
LD
000003
00003
SFT(050)
1200
1201
00004
LD
120003
00005
OUT
000500
00006
LD
000002
00007
OUT NOT
000500
00008
OUT NOT
120003
0000
01
0000
00
0000
03
1200
03
0000
02
0005
00
0005
00
1200
03
Address Instruction
Operands
Shift Instructions
Section 5-14