115
-
Appendix
2:
Label
list
Label
Type
Position
Description
Reference
A0
Terminal
name
7,
7,
7 Address
bus
0
(LSB)
(PCL6113,
6123,
6143)
P8,
17
A1
Terminal
name
8,
8,
8 Address
bus
1
(PCL6113,
6123,
6143)
P8,
17
A2
Terminal
name
9,
9,
9 Address
bus
2
(PCL6113,
6123,
6143)
P8,
17
A3
Terminal
name
10,
10 Address
bus
3
(PCL
6123,
6143)
P8,
17
A4
Terminal
name
11 Address
bus
4
(MSB)
(PCL6143)
P8,
17
ALM
Terminal
name
39
Driver
alarm
signal
(PCL
6113)
P10,
83
ALML
Register
bit
RENV1
9
Set
the
input
logic
for
the
ALM
signal
(0:
Negative,
1:
Positive)
P38,
83
ALMM
Register
bit
RENV1
8
Select
the
process
to
use
when
the
ALM
input
is
ON
(0:
Immediate
stop,
1:
Deceleration
stop)
P38,
83
ALMu
Terminal
name
134 U
axis
driver
alarm
signal
(PCL6143)
P10,
83
ALMx
Terminal
name
40,
41 X
axis
driver
alarm
signal
(PCL
6123,
6143) P10,
83
ALMy
Terminal
name
77,
72 Y
axis
driver
alarm
signal
(PCL
6123,
6143) P10,
83
ALMz
Terminal
name
102 Z
axis
driver
alarm
signal
(PCL6143)
P10,
83
AS0
to
13
Register
bit
RSPD
0-15
Monitor
current
speed
P47
Terminal
name
64
Operation
monitor
output
(PCL6113)
P13
Terminal
name
159 Operation
monitor
output
for
the
U
axis
(PCL6143)
P13
Terminal
name
65,
66 Operation
monitor
output
for
the
X
axis
(PCL
6123,
6143) P13
Terminal
name
102,
97 Operation
monitor
output
for
the
Y
axis
(PCL
6123,
6143) P13
Terminal
name
128 Operation
monitor
output
for
the
Z
axis
(PCL6143)
P13
BUFB0
Byte
map
name
4
for
Z80
Write/read
the
input/output
buffer
(bits
0
to
7).
P18,
20
BUFB1
Byte
map
name
5
for
Z80
Write/read
the
input/output
buffer
(bits
8
to
15)
P18,
20
BUFB2
Byte
map
name
6
for
Z80
Write/read
the
input/output
buffer
(bits
16
to
23)
P18,
20
BUFB3
Byte
map
name
7
for
Z80
Write/read
the
input/output
buffer
(bits
24
to
31)
P18,
20
BUFW0
Word
map
name
4
for
8086
Write/read
the
input/output
buffer
(bits
0
to
15)
P18,
21
BUFW1
Word
map
name
6
for
8086
Write/read
the
input/output
buffer
(bits
16
to
31)
P18,
21
C1S0
to
1
Register
bit
RENV3
12-13 Select
a
comparison
counter
for
comparator1
P42,
93
C1RM
Register
bit
RENV3
7
Set
COUNTER1
for
ring
count
operation
using
Comparator
1.
P42,
93
C2S0
to
1
Register
bit
RENV3
14-15 Select
a
comparison
counter
for
Comparator
2
P42,
93
C2RM
Register
bit
RENV3
11
Set
COUNTER2
for
ring
count
operation
using
Comparator
2
P42,
93
Terminal
name
77,
124,
170 Emergency
stop
signal
(PCL6113,
6123,
6143)
P8,
87
CIS1
Register
bit
RENV3
0
Set
COUNTER1
to
count
input
pulses
P42,
92
CIS2
Register
bit
RENV3
1
Set
COUNTER2
to
count
input
pulses
P42,
92
CLK
Terminal
name
69,
113,
163 Reference
clock
(19.6608
MHz
as
standard)
(PCL6113,
6123,
6143)
P7
CMEMG
Command
05h
Emergency
stop
P25,
87
CMSTA
Command
06h
Output
(simultaneous
start)
signal
P25,
85
CMSTP
Command
07h
Output
(simultaneous
stop)
signal
P25,
87
CND0
to
3
Register
bit
RSTS
0-3
Operation
status
monitor
P45
CNTD
Command
56h
Remaining
high
speed
start
pulses
(FH
low
speed
->
Deceleration
stop)
P25
CNTFH
Command
55h
Remaining
pulses
FH
low
speed
start
pulses
P25
CNTFL
Command
54h
Remaining
pulses
FL
low
speed
start
pulses
P25
CNTUD
Command
57h
Remaining
high
speed
start
pulses
(accelerate
->
FH
low
speed
->
deceleration
stop)
P25
COMB0
Byte
map
name
Write
control
command
P19
COMB1
Byte
map
name
Axis
selection
P19
COMW
Word
map
name
Assign
an
axis,
or
write
a
control
command
P19
COUNTER1
Circuit
name
28-bit
counter1
for
command
position
control
P43,
88
COUNTER2
Circuit
name
28-bit
counter2
for
mechanical
position
control
P43,
88
Terminal
name
70
Comparator
1
output
signal
for
the
X
axis
(PCL6123)
P13
Terminal
name
107
Comparator
1
output
signal
for
the
Y
axis
(PCL6123)
P13
Terminal
name
71
Comparator
2
output
signal
for
the
X
axis
(PCL6123)
P13
Terminal
name
108
Comparator
2
output
signal
for
the
Y
axis
(PCL6123)
P13
Terminal
name
4,
4,
4 Chip
select
signal
(PCL6113,
6123,
6143) P8
Terminal
name
74,
121,
167 Simultaneous
deceleration
signal
(PCL6113,
6123,
6143)
P9
CSPO
Register
bit
RENV2
13
Output
a
signal
even
though
an
axis
is
stopped
by
a
command
P40
Terminal
name
75,
122,
168 Simultaneous
start
signal
(PCL6113,
6123,
6143) P9,
85
Terminal
name
76,
123,
169 Simultaneous
stop
signal
(PCL6113,
6123,
6143)
P9,
87
CU1H
Register
bit
RENV3
2
Stop
counting
on
COUNTER1
P42,
91
CU1L
Register
bit
RENV3
4
Reset
COUNTER1
right
after
latching
the
count
value.
P42,
90
CU1R
Register
bit
RENV3
6
Reset
COUNTER1
when
the
zero
return
is
complete.
P42,
90
CU2H
Register
bit
RENV3
3
Stop
the
count
on
COUNTER2
P42,
90
CU2L
Register
bit
RENV3
8
Reset
COUNTER2
right
after
latching
the
count
value.
P42,
90
CU2R
Register
bit
RENV3
10
Reset
COUNTER2
when
the
zero
return
is
complete
P42,
90
CUN1R
Command
20h
Reset
COUNTER1
P27,
91
CUN2R
Command
21h
Reset
COUNTER2
P27,
91
D0
Terminal
name
15,
16,
17 Data
bus
0
(LSB)
(PCL6113,
6123,
6143)
P8
D1
Terminal
name
16,
17,
18 Data
bus
1
(PCL6113,
6123,
6143)
P8
D10
Terminal
name
27,
28,
29 Data
bus
10
(PCL6113,
6123,
6143)
P8
D11
Terminal
name
28,
29,
30 Data
bus
11
(PCL6113,
6123,
6143)
P8
D12
Terminal
name
30,
31,
32 Data
bus
12
(PCL6113,
6123,
6143)
P8
D13
Terminal
name
31,
32,
33 Data
bus
13
(PCL6113,
6123,
6143)
P8
D14
Terminal
name
32,
33,
34 Data
bus
14
(PCL6113,
6123,
6143)
P8
Summary of Contents for PCL6113
Page 1: ...User s Manual For PCL6113 6123 6143 Pulse Control LSI Nippon Pulse Motor Co Ltd...
Page 11: ...5 3 Terminal Assignment Diagram 3 1 PCL6113 3 2 PCL6123...
Page 20: ...14 5 Block Diagram...
Page 115: ...109 11 Stop timing by error...
Page 116: ...110 13 External Dimensions 13 1 PCL6113...
Page 117: ...111 13 2 PCL6123...
Page 118: ...112 13 3 PCL6143...