![Monroe Electronics DASDEC-II User Manual Download Page 91](http://html1.mh-extra.com/html/monroe-electronics/dasdec-ii/dasdec-ii_user-manual_1828808091.webp)
One-Net/DASDEC User Manual
5-62
v3.0 | r1016
Delay crawl
– Defaults to disabled.
• When enabled, the crawl is delayed until after the EAS audio header and
attention two-tone signal is played.
Repeat Alert Video Display
– Defaults to Do Not Repeat.
Select from a set of options for repeating the data write to the remote device
after a pause period set from the
Set Alert Video Repetition Period
field. The
repeat period has to be at least 2 minutes.
5. Sage Generic CG Attribute Settings
Serial Port Baud Rate
– Defaults to 9600.
• Select 9600 or 19200 baud depending on the remote device require
-
ments.
Serial Port Flow Control
– Select Hardware or Software or None depending
upon the hardware support on the remote device.
Throttle down serial port write speed
– Defaults to disabled.
• When Enabled, data is written with pauses between 128 byte blocks. This
can be helpful when sending this to devices that cannot do flow control.
Iterations
– Defaults to one. Crawl is done once.
• Set from 1 to 5.
Repeat Alert Video Display
– Defaults to Do Not Repeat.
• Select from a set of options for repeating the data write to the remote
device after a pause period set from the
Set Alert Video Repetition
Period
field. The repeat period has to be at least 2 minutes.
6. Sage News Room Attribute Settings
Immediate display upon matching decoded alert
– Defaults to disabled.
• When enabled, data for matching FIPS and EAS filtered alerts is sent to
the remote device using the Sage News Room protocol.
Serial Port Baud Rate
– Defaults to 9600.
• Select 9600 or 19200 baud depending on the remote device require
-
ments.
Serial Port Flow Control
– Select Hardware or Software or None depending
upon the hardware support on the remote device.
Throttle down serial port write speed
– Defaults to disabled.
• When Enabled, data is written with pauses between 128 byte blocks. This
can be helpful when sending this to devices that cannot do flow control.
7. Chyron CODI CG Attribute Settings
Font
- Defaults to one.
• Set from 1 to 8.
Color