One-Net/DASDEC User Manual
6-10
v3.0 | r0616
You can also play the audio file on your host computer by clicking on
Listen on Browser
hyperlink
. To listen to the audio, the host computer must have a WAV file player. Alerts
without an audio message will not display either the
Play->Front Panel
button or
Listen
on Browser
hyperlink.
TDX portion
If the alert has TDX details data, information is appended to the text translation for the
alert. Also, links to any TDX-provided URL information is displayed. These links can be
followed to go to web pages with more detailed information relevant to the alert. TDX
details must originate from the alert source.
Play audio alarm on browser
On the right side of the page, under the Active Decoded alert table, is the
Play audio
alarm on browser when page has unacknowledged, active unforwarded alert
check
box to control an audible browser announcement for active, decoded alerts that have
not yet been acknowledged or forwarded. Enabling this option on a speaker-equipped
computer, along with an auto-refresh, can audibly notify control room staff that an
alert has been decoded. Every time the browser page refreshes while a decoded alert
remains unacknowledged and unforwarded, an audio recording of the three burst
EAS end-of-message “noise” will play over the host computer’s speakers. The audio
notification will stop once the alert is forwarded or acknowledged. An alert can be
acknowledged using the
Acknowledge Pending Alert
button on the active alert status
display, by pressing the EAS device’s Front Panel button, or a programmed GPIO input
closure.
Incoming & Incoming/Decoded Alerts: Multistation Mode
The active decoded alerts display supports MultiStation mode. You can view the active
(enabled) stations on the right side of the page above the active decoded alerts table.
Within the active decoded alert status, a target station ID and a
Forward Alert
button is
displayed for each enabled station. Alerts can be forwarded to any station by pressing
the appropriate
Forward Alert
button. The screen shot below shows one active,
unacknowledged decoded alert, with two available enabled station targets and thus,
two
Forward Alert
buttons, one per station. A single
Acknowledge Pending Alert
and
Edit/Review Forwarding Text/Audio
button is provided to cover MultiStation mode.
Note
Adobe Flash Player
must be installed for
the audio notification to
work.
Note
In MultiStation mode,
to customize the alert
audio/text translation,
you must run the
Edit/Review process
separately before
station forwarding.