![Monroe Electronics DASDEC-II User Manual Download Page 9](http://html1.mh-extra.com/html/monroe-electronics/dasdec-ii/dasdec-ii_user-manual_1828808009.webp)
One-Net/DASDEC User Manual
1-3
v3.0 | r1016
Select Button
The Select button on the front panel is used to manually initiate a Required Weekly Test
(RWT), or to acknowledge unforwarded active alerts.
• Press the Select button once to being a manual RWT; the second line of the LCD
displays
Press again for RWT
. Press the Select button a second time to begin the
RWT alert. (See Chapter 7 - One Button Alert for more information.)
• When an alert has been decoded and is waiting to be forwarded, press the Select
button to acknowledge that alert. The LCD temporally shows
Acknowledging
.
BACK PANEL
The back panel provides all of the connections necessary for the EAS device.
Back Panel
1
Program Audio / Aux. Audio 4
Terminal Block
10
Main Audio - Line Input 1 & 2
2
Radio Antenna Connectors
(Radio 1, 2, & 3)
11
Triple Port Gigabit Ethernet
Expansion (optional)
3
General Purpose Input/Output
Terminal Block
12
Main Network Interface
4
BNC Video Out (optional)
13
USB Ports
5
Power Switch
14
Second Network Interface
6
Expansion Slot
15
VGA
7
AES Program Audio (optional)
16
Serial Port (COM1)
8
Aux. Audio - Line Input 3 & 4
17
PS/2 Port
9
EAS Audio Out
18
Power Receptacle
Note
The unit provides
software support
for the Video Out,
Ethernet Expansion,
and AES Program Audio
as licensed options.
Any connections not
labeled, such as HDMI,
are not supported and
are not operational.