One-Net/DASDEC User Manual
5-71
v3.0 | r1016
> EAS Code Groups
sub-tab and can quickly be accessed by clicking the
Event
Codes
hyperlink. Only one selection may be made from this pull-down menu.
Orig (Originator) Codes
This is a three character ASCII code found in an EAS header which denotes the
source of an EAS alert. Select one or a combination of Originator Codes from
the list. Pressing the CTRL key while clicking input sources will allow the user to
select multiple sources. The current FCC rules define four available ORG Codes:
•
EAS – Broadcast Station/Cable System
•
CIV – Civil Authority
•
WXR – National Weather Service
•
PEP – Primary Entry Point
Station ID
Found in the EAS header is the identification of the specific station that
originated the EAS alert. Enter the appropriate station ID into this text field.
Using an asterisk (*) will allow all station IDs.
Action
There are two available Action options found in this pull-down menu:
•
Deactivate/Log Only
•
Activate
The
Deactivate/Log Only
option will log the incoming EAS alert and perform no fur
-
ther actions. The Action Definition interface will not be visible and no actions may
be configured.
Selecting
Activate
will make the Action Definition interface visible and configurable.
Editing a Custom Alert Node
Action Definition
The following settings are available when an Alert Node Action is set to
Activate
:
•
Forwarding Action
•
GPI Hold
•
Pre-Alert Audio
•
Alert Audio
•
Post EOM Omnilingual Audio
•
Post-Alert Audio
Forwarding Action
There are five available options from this pull-down menu:
•
Block Forwarding
– will NOT forward the EAS alert defined in this
Alert Node.
•
Manual
– requires manual forwarding of the EAS alert defined in this
Alert Node (GPI or manual forwarding)