![Monroe Electronics DASDEC-II User Manual Download Page 90](http://html1.mh-extra.com/html/monroe-electronics/dasdec-ii/dasdec-ii_user-manual_1828808090.webp)
One-Net/DASDEC User Manual
5-61
v3.0 | r1016
TFT Pre-Alert Notification omit audio play-out
• Check to play audio if TFT client requests EAS alert audio play-out. If
disabled, the audio requests will be immediately answered without audio
play-out.
TFT client relay command emulation
– Defaults to disabled.
• When disabled, the standard EAS Audio relays are used. When enabled,
requests by the TFT client for relays will be mapped to the GPIO output
relays.
Max Delay before forced play-out
– Defaults to 13 minutes.
• Set this value in minutes: seconds from 2 minutes, 10 seconds up to a
maximum of 13 minutes. This is the maximum time that can elapse after a
successful EAS ready to play notification to a remote TFT protocol device
before the EAS audio will be force played.
Pre/Post Alert Audio extension
– Defaults to disabled.
• When enabled, TFT client audio play commands will use pre and post
alert audio if they are defined.
Serial Port Flow Control
– Select Hardware or Software or None depending
upon the hardware support on the remote device.
4. VDS CG Attribute Settings
Crawl Font
– Defaults to one.
• Set from 1 to 4.
Char Color
– Defaults to white.
Set Color Background by EAS Severity?
– Defaults to disabled.
• When enabled, the text color is determined based on a color selection set
for the EAS severity category.
Iterations
– Defaults to one. Crawl is done once.
• Set from 1 to 100.
Speed
– Defaults to Fast.
• Choose from three speeds: Fast, Medium or Slow.
VDS Mode
– Defaults to VDS840.
• Select from VDS840, VDS830, Starmu/Star8 and Sage Emulation. The Sage
Emulation mode has an optional page of text that can be programmed.
Vertical position
– Defaults to video 20.
• Set from 20 (topmost) to 208 (bottommost).
Serial Port Baud Rate
– Defaults to 9600 Select 9600 or 19200 baud
depending on the remote CODI device requirements.
Serial Port Bit Config Rate
– Set data bits and stop bits depending on the
remote VDS device requirements.