![Monroe Electronics DASDEC-II User Manual Download Page 133](http://html1.mh-extra.com/html/monroe-electronics/dasdec-ii/dasdec-ii_user-manual_1828808133.webp)
One-Net/DASDEC User Manual
5-104
v3.0 | r1016
Audio Output Sample Rate
The correct value for this depends on the destination. For audio to a remote EAS device
EAS NET decoder, use the output sample rate selected on the remote EAS device.
Choices are 16000, 32000, 44100, and 48000 samples/sec.
Pre-Alert audio/alert header/attention inclusion at start of audio stream
Alert EOM Audio Streaming
These two check box options are included for control of the total content of the alert
audio that is streamed. For purposes of this interface, alert audio consists of three
parts:
•
Pre-Alert audio/EAS Alert FSK header/Alert Attention signal
•
Alert audio voice message
•
Alert FSK EOM audio
No matter the choices, the second part, alert audio voice message, if it exists, is always
streamed. Any combination of these options will work when streaming to a remote EAS
device EAS NET decoder. The default is to not stream the header or EOM sequence, just
the audio voice message. Use the options as required by the specific application on a
remote server.
To review, the options allow the inclusion/exclusion of:
•
Pre-Alert audio/EAS Alert FSK header/Alert Attention signal
•
EAS alert FSK EOM
Delay time before stream start, Starting silence duration, Ending silence duration
These options allow streaming to be delayed by the duration of the alert header. Three
numeric text fields allow entry of three additional audio delay components. Each delay
is in seconds and applies to a specific location during the audio stream. Use as needed
for the specific application.
Configure EAS NET Clients
Two check box are displayed for enabling EAS_NET during alert forwarding and
origination.
Forwarded Alerts can be sent to EAS_NET devices
This check box enables EAS_NET send processing during alert forwarding. It can be
enabled / disabled at any time.
Encoder Originated Alerts can be sent to EAS_NET devices
This check box enables EAS_NET send processing during alert origination. It can be
enabled / disabled at any time.
Decoded Alerts Can be sent to EAS_NET devices
This check box enables EAS_NET send processing during alert decoding. Decoded alerts
can be sent to another EAS_NET device without forwarding and putting it on the air.
Note
At least one of these check
boxes must be enabled to
allow editing of EAS
_
NET
clients.