Precautions for maintenance and inspection
Inspection item
FR-F800
7 - 5
7.1.5 Cleaning
Always run the inverter in a clean status.
When cleaning the inverter, gently wipe dirty areas with a soft cloth immersed in neutral detergent or
ethanol.
7.1.6 Replacement
of
parts
The inverter consists of many electronic parts such as semiconductor devices.
The following parts may deteriorate with age because of their structures or physical characteristics,
leading to reduced performance or fault of the inverter. For preventive maintenance, the parts must
be replaced periodically.
Use the life check function as a guidance of parts replacement.
Estimated lifespan for when the yearly average surrounding air temperature is 40 °C.
(Without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
Output current: 80% of the inverter rating
NOTES
Do not use solvent, such as acetone, benzene, toluene and alcohol, as these will cause the inverter
surface paint to peel off.
The display, etc. of the operation panel and the parameter unit are vulnerable to detergent and
alcohol. Therefore, avoid using them for cleaning.
Part name
Estimated lifespan
Description
Cooling fan
10 years
Replace (as required)
Main circuit smoothing capacitor
10 years
Replace (as required)
On-board smoothing capacitor
10 years
Replace the board (as required)
Relays
⎯
As required
Main circuit fuse
(FR-F840-04320(185K) or higher)
10 years
Replace the fuse (as required)
Tab. 7-3:
Wearing parts
NOTES
For parts replacement, contact the nearest Mitsubishi FA center.
Summary of Contents for FR-F800
Page 2: ......
Page 4: ......
Page 28: ...Related manuals Introduction 1 8 ...
Page 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Page 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 806: ...Outline dimension drawings Specifications 8 26 ...
Page 833: ......