Parameters
(A) Application parameters
FR-F800
5 - 333
Operation
●
Procedure for operation
●
Signal operation after setting parameters
I002672E
Fig. 5-150:
Operation procedure
Status
MRS
CS
STF
MC1
MC2
MC3
Remarks
Power ON
OFF
(OFF)
OFF
(OFF)
OFF
(OFF)
OFF
→
ON
(OFF
→
ON)
OFF
(OFF)
OFF
→
ON
(OFF
→
ON)
External operation
mode
(PU operation mode)
At start
(Inverter)
OFF
→
ON OFF
→
ON OFF
→
ON
ON
OFF
ON
During constant-
speed operation
(commercial power
supply)
ON
ON
→
OFF
ON
ON
OFF
→
ON ON
→
OFF
MC2 turns ON after MC3
turns OFF.
Waiting time is 2 s (while
coasting).
For deceleration,
switched to the
inverter operation
(inverter)
ON
OFF
→
ON
ON
ON
ON
→
OFF OFF
→
ON
MC3 turns ON after MC2
turns OFF.
Waiting time is 4 s (while
coasting).
Stop
ON
ON
ON
→
OFF
ON
OFF
ON
Tab. 5-160:
Signals after parameter setting
Pr. 135 = "1" (open collector output terminal of inverter)
Pr. 136 = "2.0 s"
Pr. 137 = "1.0 s" (Set the time until MC3 is actually turned ON and the
inverter and motor are electrically connected. If the time is short, the
restart may not function properly.)
Pr. 57 = "0.5 s"
Pr. 58 = "0.5 s" (Always set this to switchover from the commercial power
supply operation to the inverter operation.)
Power supply ON
Setting the parameters
Start inverter operation
Constant-speed commercial
power supply operation
Deceleration (stop)
inverter operation
Summary of Contents for FR-F800
Page 2: ......
Page 4: ......
Page 28: ...Related manuals Introduction 1 8 ...
Page 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Page 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 806: ...Outline dimension drawings Specifications 8 26 ...
Page 833: ......