Appendix
Parameters (functions) and instruction codes under different control methods
FR-F800
A - 21
1216
Limit cycle output lower limit
10
90
C
1217
Limit cycle hysteresis
11
91
C
1218
PID gain tuning setting
12
92
C
1219
PID gain tuning start/status
13
93
C
x
x
x
1361
Detection time for PID output hold
3D
BD
D
1362
PID output hold range
3E
BE
D
1363
PID Priming time
3F
BF
D
1364
Stirring time during sleep
40
C0
D
1365
Stirring interval time
41
C1
D
1366
Sleep boost level
42
C2
D
1367
Sleep boost waiting time
43
C3
D
1368
Output interruption cancel time
44
C4
D
1369
Check valve closing completion frequency
45
C5
D
1370
Detection time for PID limiting operation
46
C6
D
1371
PID upper/lower limit prewarning level range
47
C7
D
1372
PID measured value control set point change
amount
48
C8
D
1373
PID measured value control set point change rate
49
C9
D
1374
Auxiliary pressure pump operation starting level
4A
CA
D
1375
Auxiliary pressure pump operation stopping level
4B
CB
D
1376
Auxiliary motor stopping level
4C
CC
D
1377
PID input pressure selection
4D
CD
D
1378
PID input pressure warning level
4E
CE
D
1379
PID input pressure fault level
4F
CF
D
1380
PID input pressure warning set point change
amount
50
D0
D
1381
PID input pressure fault operation selection
51
D1
D
1460
PID multistage set point 1
3C
BC
E
1461
PID multistage set point 2
3D
BD
E
1462
PID multistage set point 3
3E
BE
E
1463
PID multistage set point 4
3F
BF
E
1464
PID multistage set point 5
40
C0
E
1465
PID multistage set point 6
41
C1
E
1466
PID multistage set point 7
42
C2
E
1469
Number of cleaning times monitor
45
C5
E
x
x
x
1470
Number of cleaning times setting
46
C6
E
1471
Cleaning trigger selection
47
C7
E
1472
Cleaning reverse rotation frequency
48
C8
E
1473
Cleaning reverse rotation operation time
49
C9
E
1474
Cleaning forward rotation frequency
4A
CA
E
1475
Cleaning forward rotation operation time
4B
CB
E
1476
Cleaning stop time
4C
CC
E
1477
Cleaning acceleration time
4D
CD
E
1478
Cleaning deceleration time
4E
CE
E
Pr.
Name
Instruction code
Control method
Parameter
Read
Wr
it
e
Ext
e
n
d
e
d
Co
p
y
Clea
r
Al
l cl
ea
r
Tab. A-3:
Parameter list with instruction codes (17)
V/F
V/FV/FV/F
Magnetic fluxMagnetic fluxMagnetic flux
PMPMPM
Summary of Contents for FR-F800
Page 2: ......
Page 4: ......
Page 28: ...Related manuals Introduction 1 8 ...
Page 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Page 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 806: ...Outline dimension drawings Specifications 8 26 ...
Page 833: ......