Parameters (functions) and instruction codes under different control methods
Appendix
A - 6
21
Acceleration/deceleration time increments
15
95
0
22
Stall prevention operation level
16
96
0
23
Stall prevention operation level compensation
factor at double speed
17
97
0
x
24
Multi-speed setting (speed 4)
18
98
0
25
Multi-speed setting (speed 5)
19
99
0
26
Multi-speed setting (speed 6)
1A
9A
0
27
Multi-speed setting (speed 7)
1B
9B
0
28
Multi-speed input compensation selection
1C
9C
0
29
Acceleration/deceleration pattern selection
1D
9D
0
30
Regenerative function selection
1E
9E
0
31
Frequency jump 1A
1F
9F
0
32
Frequency jump 1B
20
A0
0
33
Frequency jump 2A
21
A1
0
34
Frequency jump 2B
22
A2
0
35
Frequency jump 3A
23
A3
0
36
Frequency jump 3B
24
A4
0
37
Speed display
25
A5
0
41
Up-to-frequency sensitivity
29
A9
0
42
Output frequency detection
2A
AA
0
43
Output frequency detection for reverse rotation
2B
AB
0
44
Second acceleration/deceleration time
2C
AC
0
45
Second deceleration time
2D
AD
0
46
Second torque boost
2E
AE
0
x
x
47
Second V/F (base frequency)
2F
AF
0
x
x
48
Second stall prevention operation level
30
B0
0
x
49
Second stall prevention operation frequency
31
B1
0
x
50
Second output frequency detection
32
B2
0
51
Second electronic thermal O/L relay
33
B3
0
52
Operation panel main monitor selection
34
B4
0
54
FM/CA terminal function selection
36
B6
0
55
Frequency monitoring reference
37
B7
0
56
Current monitoring reference
38
B8
0
57
Restart coasting time
39
B9
0
58
Restart cushion time
3A
BA
0
x
59
Remote function selection
3B
BB
0
60
Energy saving control selection
3C
BC
0
x
65
Retry selection
41
C1
0
66
Stall prevention operation reduction starting
frequency
42
C2
0
x
67
Number of retries at fault occurrence
43
C3
0
68
Retry waiting time
44
C4
0
69
Retry count display erase
45
C5
0
70
Parameter for manufacturer setting. Do not set.
Pr.
Name
Instruction code
Control method
Parameter
Read
Wr
it
e
Ext
e
n
d
e
d
Co
p
y
Clea
r
Al
l cl
ea
r
Tab. A-3:
Parameter list with instruction codes (2)
V/F
V/FV/FV/F
Magnetic fluxMagnetic fluxMagnetic flux
PMPMPM
Summary of Contents for FR-F800
Page 2: ......
Page 4: ......
Page 28: ...Related manuals Introduction 1 8 ...
Page 104: ...Connection of stand alone option units Installation and wiring 2 76 ...
Page 162: ...Basic operation procedure JOG operation Basic operation 4 32 ...
Page 806: ...Outline dimension drawings Specifications 8 26 ...
Page 833: ......