C70 Setup Manual
Appendix 1.6 Spindle Parameters
321
【
#13087
】
SP087 FHz4 Notch filter frequency 4
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
Related parameters: SP034/bitB-9
---Setting range---
0 to 2250 (Hz)
【
#13088
】
SP088 FHz5 Notch filter frequency 5
Set the vibration frequency to suppress when machine vibration occurs.
(Enabled at 50 or more.)
When not using, set to "0".
Related parameters: SP034/bitF-D
---Setting range---
0 to 2250 (Hz)
【
#13089
】
SP089 TMKQ Spindle output stabilizing gain Q axis
Set the magnification of the torque current stabilizing gain. (For machine tool builder adjustment)
When set to "0", the torque current stabilization is disabled.
When not using, set to "0".
---Setting range---
0 to 32767
【
#13090
】
SP090 TMKD Spindle output stabilizing gain D axis
Set the magnification of the excitation current stabilizing gain. (For machine tool builder adjustment)
When set to "0", the excitation current stabilization is disabled.
When not using, set to "0".
---Setting range---
0 to 32767
【
#13091
】
SP091
Not used. Set to "0".
【
#13092
】
SP092
Not used. Set to "0".
【
#13093
】
SP093
Not used. Set to "0".
【
#13094
】
SP094 MPV Magnetic pole error detection speed
In the magnetic pole position detection function, the command motor speed and motor speed during
the position command stop are monitored.
Set the command motor speed level and motor speed level during the position command stop in "r/
min" unit.
When the command motor speed level is set to "0", the magnetic pole position error is detected at
10r/min.
Set to "10" as a standard setting when the magnetic pole position error detection function is enabled.
This detects the magnetic pole position error when the motor speed is "100r/min".
Ten-thousands digit, Thousands digit ------------ Command motor speed level (10r/min)
Hundreds digit, Tens digit, Ones digit ----------- Motor speed level (10r/min)
---Setting range---
0 to 31999
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......