C70 Setup Manual
Appendix 1.3 Base Specifications Parameters
229
【
#21158(PR)
】
SC_EQP_4 Safety device mounting information 4
Set the devices' mount status when the device manufacturer's safety sequence is shared by
machines with different safety device configurations.
Each bit's data is copied to M840 - M847 respectively at every power ON, which may be used in the
device manufacturer's safety sequence on both NC-side and PLC-side.
Each bit corresponds to the following device No.
bit0: M840
bit1: M841
bit2: M842
bit3: M843
bit4: M844
bit5: M845
bit6: M846
bit7: M847
---Setting range---
00000000 to 11111111
【
#21159(PR)
】
SC_EQP_CHK3 Safety device mounting information check 3
Use this parameter to prevent the incorrect setting of "#21157 SC_EQP_3 (Safety device mounting
information 3)".
Set the same value as in "#21157 SC_EQP_3 (Safety device mounting information 3)".
Each bit's data is copied to M848 - M855 respectively at the power ON.
Each bit corresponds to the following device No.
bit0: M848
bit1: M849
bit2: M850
bit3: M851
bit4: M852
bit5: M853
bit6: M854
bit7: M855
---Setting range---
00000000 to 11111111
【
#21160(PR)
】
SC_EQP_CHK4 Safety device mounting information check 4
Use this parameter to prevent the incorrect setting of "#21158 SC_EQP_4 (Safety device mounting
information 4)".
Set the same value as in "#21158 SC_EQP_4 (Safety device mounting information 4)".
Each bit's data is copied to M856 - M863 respectively at the power ON.
Each bit corresponds to the following device No.
bit0: M856
bit1: M857
bit2: M858
bit3: M859
bit4: M860
bit5: M861
bit6: M862
bit7: M863
---Setting range---
00000000 to 11111111
【
#21161(PR)
】
SftySgnl ChkTrg Dual signal check-time change
Set this parameter to change the dual signal module's output ON/OFF check time and the contactor
welding detection start time after the power ON.
0: Automatically start checking after the power ON
1: Start checking at the rising edge of the "Dual signal check start (G+001/Y311)" signal.
(Note) Setting "1" is allowed only when the power supply to I/Os is impossible at the controller's
power ON.
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......