C70 Setup Manual
2.1 GT Designer3
7
2.1.2 Making Communication Settings
Make communication settings on a GT Designer3 project.
Refer to the following according to the connection type you use.
- Ethernet connection (for GT16): Section 2.1.2.1
- Ethernet connection (for GT15): Section 2.1.2.2
- Bus connection (for GT15/GT16): Section 2.1.2.3
2.1.2.1 Setting Ethernet Connection (for GT16)
This section explains the setting procedure for Ethernet connection of GOT1000 Series GT16.
Connect a Ethernet cable to the CNC CPU module and the GOT Ethernet interface.
The following two IP addresses need to be set in order to establish the Ethernet connection.
GOT's IP address (192.168.1.1 in this manual)
CNC CPU module's IP address (192.168.1.2)
(Note 1) When connecting to a personal computer and a module with USB interface, an electric shock or a module
failure may occur depending on the model of a personal computer or the service condition.
Be sure to refer to "Items related to connection" on "Precautions for Safety" before connecting them.
(Note 2) Unless there is a specific reason, set the CNC CPU default IP address (192.168.1.2). If any other IP adress is
set, the backup data created with GOT backup and restore function cannot be restored to the replaced CNC
CPU module, which has a default IP address.
Setting procedures without using the "New Project Wizard" on GT Designer3 are as follows.
GOT1000 Series GT16
(SVGA / XGA)
GT Designer3
CNC CPU
Q173NCCPU
IP address: 192.168.1.2
IP address: 192.168.1.1
GT09-C20USB-5P
GT09-C30USB-5P
or
USB
100BASE-T
Cross
100BASE-T
Straight
or
Rear view
Ethernet interface
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......