C70 Setup Manual
Appendix 1.6 Spindle Parameters
291
【
#3050
】
sprlv Spindle synchronization rotation speed attainment level
Set the level of speed difference between the basic and synchronous spindles during spindle
synchronization control. Setting of the synchronous spindle side is enabled. When the difference
becomes below the setting level, the spindle speed synchronization complete signal will turn ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
【
#3051
】
spplv Spindle phase synchronization attainment level
Set the level of phase difference between the basic and synchronous spindles during spindle
synchronization. Setting of the synchronous spindle side is validated. When the difference becomes
below the setting level, the spindle phase synchronization complete signal will go ON.
---Setting range---
0 to 4095 (pulse) (1 pulse = 0.088°)
【
#3052
】
spplr Spindle synchronization relative polarity
Set the spindle motor and spindle's relative polarity.
0: Positive polarity
(Spindle CW rotation at motor CW rotation)
1: Negative polarity
(Spindle CCW rotation at motor CW rotation)
【
#3053
】
sppst Spindle encoder Z -phase position
Set the deviation amount from the spindle's basic point to the spindle encoder's Z phase.
Obtain the deviation amount, considering a clockwise direction as positive when viewed from the
spindle's front side.
---Setting range---
0 to 359999 (1/1000°)
【
#3054
】
sptc1 Spindle synchronization multi-step acceleration/deceleration changeover
speed 1
Set the speed which switches from 1st step to 2nd step in spindle synchronization multi-step
acceleration/deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
【
#3055
】
sptc2 Spindle synchronization multi-step acceleration/deceleration changeover
speed 2
Set the speed which switches from 2nd step to 3rd step in spindle synchronization multi-step
acceleration/deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
【
#3056
】
sptc3 Spindle synchronization multi-step acceleration/deceleration changeover
speed 3
Set the speed which switches from 3rd step to 4th step in spindle synchronization multi-step
acceleration/deceleration control. Set the same value for the reference axis and synchronous axis.
Set the value of limit rotation speed (slimit) or higher not to carry out a step shift.
---Setting range---
0 to 99999 (r/min)
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......