Appendix 2.16.3.3 Troubleshooting for each warning No.
Warning No.
96
Scale feedback error
An excessive difference in feedback amount was detected between the main side detector and the MPI scale in MPI scale
absolute position detection system.
Investigation details
Investigation results
Remedies
SV
SP
1
Check if there is any abnormality in the
detector's ambient environment.
(Ex. Ambient temperature, noise,
grounding)
Take remedies according to the causes of the abnormality in the ambient environment.
2
Check the repeatability.
Occurs frequently.
Replace the detector.
Is not repeated.
Check the investigation item No. 1.
Warning No.
97
Scale offset error
An error was detected in the offset data that is read at the NC power-ON in MPI scale absolute position detection system.
Investigation details
Investigation results
Remedies
SV
SP
1
Check if there is any abnormality in the
detector's ambient environment.
(Ex. Ambient temperature, noise,
grounding)
Take remedies according to the causes of the abnormality in the ambient environment.
2
Check the repeatability.
Occurs frequently.
Replace the detector.
Is not repeated.
Check the investigation item No. 1.
Warning No.
9B
Incremental detector/magnetic pole shift warning
For the incremental detector, an error was detected in the magnetic pole shift amount set in the magnetic pole shift amount
parameter "SV028".
Investigation details
Investigation results
Remedies
SV
SP
1
Check if there is any abnormality in the
detector's ambient environment.
(Ex. Ambient temperature, noise,
grounding)
Take remedies according to the causes of the abnormality in the ambient environment.
2
Check the repeatability.
Occurs occasionally.
Execute magnetic pole detection control
again and reset SV028.
Is not repeated.
Check the investigation item No. 1.
Warning No.
9E
Absolute position detector: Revolution counter error
An error was detected in the revolution counter of the absolute position detector. The absolute position data cannot be
compensated.
Investigation details
Investigation results
Remedies
SV
SP
1
Check if there is any abnormality in the
detector's ambient environment.
(Ex. Ambient temperature, noise,
grounding)
Take remedies according to the causes of the abnormality in the ambient environment.
2
Check the repeatability.
Occurs frequently.
Replace the detector.
Is not repeated.
Check the investigation item No. 1.
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......