Appendix 1.3 Base Specifications Parameters
183
【
#1065
】
JOG_H JOG response type
Set the JOG responsiveness type.
0: Conventional specification
JOG is started or stopped by a signal via ladder without reference to an external signal input.
1: Type 1
JOG is started or stopped by an external signal.
2: Type 2
JOG is started or stopped by logical AND of an external signal and a signal via ladder.
3: Type 3
JOG is started when a signal via ladder rises. It is stopped when an external signal and a signal
via ladder fall.
4: Type 4
Reference position return mode:
JOG is started or stopped by a signal via ladder without reference to an external input signal
(conventional specification).
Non-reference position return mode:
JOG is started or stopped by logical AND of an external signal and a signal via ladder (type 2).
---Setting range---
0 to 4
【
#1066
】
JOG_HP Select JOG activation (+) device
Set the device No. to input +JOG activation signal.
The device type is specified by "#1071 JOG_D".
The effective setting range varies depending on the device type.
A value specified outside of the effective range is invalid.
---Setting range---
X: 0000 to 02FF (hexadecimal)
M: 0000 to 8191 (decimal)
【
#1067
】
JOG_HN Select JOG activation (-) device
Set the device No. to input -JOG activation signal.
The device type is specified by "#1071 JOG_D".
The effective setting range varies depending on the device type.
A value specified outside of the effective range is invalid.
---Setting range---
X: 0000 to 02FF (hexadecimal)
M: 0000 to 8191 (decimal)
【
#1068(PR)
】
slavno Secondary axis number
Set the axis number of the secondary axis in synchronous control.
The axis number is an NC number excluding the spindle and PLC axis.
Two or more secondary axes cannot be set for one primary axis.
This parameter cannot be set for a secondary axis.
When using the multi-part system, the relation of the primary axis and secondary axis cannot extend
over part systems.
0: No secondary axis
1 to 8: First to eighth axis
【
#1069
】
no_dsp Axis with no counter display
Select whether to display the axis counter or not.
This setting is enabled on the counter display screen (relative position counter, etc.).
0: Display
1: Not display
【
#1070
】
axoff Axis removal
Select whether to enable or disable axis removal control.
0: Disable
1: Enable
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......