Appendix 1 Explanation of Parameters
MITSUBISHI CNC
220
【
#21029
】
NCname
Set this to display the NC unit name on the CE terminal screen.
---Setting range---
8 or less alphanumeric characters
【
#21030
】
AlmHold (h)
Set the time to delete sampling data automatically after an alarm occurs.
If "0" is set, the alarm will not be deleted automatically.
---Setting range---
0 to 9999 (h)
【
#21031
】
UnitMax
Set the number of control units to connect when setting and displaying several NC units with one
terminal using the multiple NC common display function. Up to 15 NC control units can be
connected.
As the default value is "0", the number of NC units to connect will be regarded as one unless you set
this parameter.
(The setting values "0" and "1" are handled in the same manner.)
---Setting range---
0 to 15 (Default value : 0)
【
#21032
】
UnitNum
Set the control unit's station No. when setting and displaying several NC units with one terminal
using the multiple NC common display function.
"0" is the first station No. and "14" is the last station No.
Make sure that the stations are not set in duplicate.
---Setting range---
0 to 14 (Default value: 0)
【
#21033
】
KeyCtrlLmt
Select the limit type of key operation right acquisition.
0: Enable the acquisition of key operation right from another display unit for all the screens.
1: Disable the acquisition of key operation right while the program screen is opened.
2: Disable the acquisition of key operation right from another display unit for all the screens.
【
#21034
】
ReMonDisp
Select the display limitation of the remote monitor tool.
0: Not limit the remote monitor tool displays.
1: Not send the display information to the remote monitor tool.
(Note) Avoid setting from the remote monitor tool.
The display will not appear from the time you set this parameter.
【
#21035
】
ComErrDly Communication alarm display delay
Displaying the error and storing the error in the alarm history will be delayed for the set time duration
when a communication error (Y02 System alarm 0051) occurs.
Set this parameter if a communication error occurs when turning OFF the power. If not (if not using),
set to "0".
---Setting range---
0 to 5000 (ms)
【
#21036
】
SrvAlmDly Servo alarm display delay
Displaying the error and storing the error in the alarm history will be delayed for the set time duration
when a servo/spindle alarm occurs.
Set this parameter if a servo/spindle alarm occurs when turning OFF the power. If not (or if not
using), set to "0".
---Setting range---
0 to 5000 (ms)
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......