Appendix 1 Explanation of Parameters
MITSUBISHI CNC
358
【
#29058(PR)
】
Production inhibit time Slave node: Production inhibit time
Set the production inhibit time.
Setting details vary depending on the connection type.
The standard setting is "0".
"0" is regarded as 10(ms).
Other settings are regarded as "(Set value) - 1"(ms).
---Setting range---
0 to 65535
【
#29061(PR)
】
Master Function Comm.Status Master function communication status
Set a device to store the following data:
<Higher byte>
The master function I/O communication status is stored.
00(HEX): OFFLINE; being initialized
40(HEX): STOP; I/O communication being stopped
C0(HEX): OPERATE; I/O communication in progress
The communication status above varies according to the auto communication start setting (address:
0631H):
- When "0: Not automatically start" is set:
Turning the power ON automatically changes the status from OFFLINE (00(HEX)) to STOP
(40(HEX)).
Turning ON the I/O communication request (Y11) changes the state to OPERATE (C0(HEX)).
- When "1: Automatically start" is set:
Turning the power ON automatically changes the status from OFFLINE (00(HEX)) to OPERATE
(C0(HEX)).
If a reset message is received from the network, the status automatically returns to OFFLINE
(00(HEX)) and makes transitions from OFFLINE (00(HEX)) to OPERATE (C0(HEX)).
<Lower byte>
The network's communication status is stored.
Each bit is turned ON/OFF as follows, according to the communication status.
---Setting range---
Within the number of device points set in the PC parameter's device setting.
【
#29062(PR)
】
Master Function Error Inform. Master function error information
Set a device to store the following data:
<Higher byte>
The communication error code occurred in the master function is stored.
<Lower byte>
The node No. (MAC ID) of the node where the error occurred is stored.
FE, FF(HEX) (254, 255): Local node (QJ71DN91)
00 to 3F(HEX) (0 to 63): Node No. (MAC ID) of the slave node where the error occurred.
---Setting range---
Within the number of device points set in the PC parameter's device setting.
Bit 7 6 5 4 3 2 1 0
Bit7-4: Always sets to OFF.
Bit3: Network has a fatal problem
and communication cannot be continued.
Bit2: Parameter error
Bit1: Always sets to OFF.
Bit0: There is a station with a communication error.
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......