Appendix 1 Explanation of Parameters
MITSUBISHI CNC
290
【
#3044
】
tapt24 Synchronous tapping 2nd step acceleration/deceleration time constant
(Gear: 11)
Set the time constant for synchronous tapping 2nd step linear acceleration/deceleration control
when gear 11 is selected.
---Setting range---
1 to 5000 (ms)
【
#3045
】
tapt31 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 00)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gear 00 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of
slimit1(#3001) to tapt31(#3045).
---Setting range---
1 to 5000 (ms)
【
#3046
】
tapt32 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 01)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gear 01 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of
slimit2(#3002) to tapt32(#3046).
---Setting range---
1 to 5000 (ms)
【
#3047
】
tapt33 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 10)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gear 10 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of
slimit3(#3003) to tapt33(#3047).
---Setting range---
1 to 5000 (ms)
【
#3048
】
tapt34 Synchronous tapping 3rd step acceleration/deceleration time constant
(Gear: 11)
Set the time constant for synchronous tapping 3rd step linear acceleration/deceleration control when
gear 11 is selected.
The inclination of linear acceleration/deceleration control for 3rd step is determined by the ratio of
slimit4(#3004) to tapt34(#3048).
---Setting range---
1 to 5000 (ms)
【
#3049
】
spt Spindle synchronization acceleration/deceleration time constant
Set the acceleration/deceleration time constant under spindle synchronization control.
The inclination of acceleration/deceleration control is determined by the ratio to limit rotation speed
(slimit). Set the same value for the reference axis and synchronous axis.
The time constant for 2nd step or subsequent steps is the magnification setting on the basis of this
setting value.
---Setting range---
0 to 9999 (ms)
Summary of Contents for C70
Page 1: ......
Page 3: ......
Page 9: ......
Page 11: ......
Page 13: ......
Page 18: ...1 1 Outline ...
Page 21: ...1 Outline MITSUBISHI CNC 4 ...
Page 22: ...5 2 GOT Initial Setup ...
Page 73: ...2 GOT Initial Setup MITSUBISHI CNC 56 ...
Page 74: ...57 3 PLC CPU Initial Setup ...
Page 91: ...3 PLC CPU Initial Setup MITSUBISHI CNC 74 ...
Page 92: ...75 4 CNC CPU Initial Setup ...
Page 105: ...4 CNC CPU Initial Setup MITSUBISHI CNC 88 ...
Page 106: ...89 5 Connecting and Setting up Multiple CNC CPU Modules ...
Page 115: ...5 Connecting and Setting up Multiple CNC CPU Modules MITSUBISHI CNC 98 ...
Page 116: ...99 6 Setting Machine Parameters ...
Page 130: ...113 7 Setting the Position Detection System ...
Page 153: ...7 Setting the Position Detection System MITSUBISHI CNC 136 ...
Page 154: ...137 8 Deceleration Check ...
Page 159: ...8 Deceleration Check MITSUBISHI CNC 142 ...
Page 160: ...143 9 Setting the Tool Entry Prohibited Range ...
Page 169: ...9 Setting the Tool Entry Prohibited Range MITSUBISHI CNC 152 ...
Page 170: ...153 10 Data Backup and Restoration ...
Page 184: ...167 Appendix 1 Explanation of Parameters ...
Page 435: ...Appendix 1 Explanation of Parameters MITSUBISHI CNC 418 ...
Page 436: ...419 Appendix 2 Explanation of Alarms ...
Page 608: ...591 Appendix 3 Display on 7 segment LED ...
Page 624: ......
Page 628: ......