MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.3 Real Time Clock (RTC)
10.3.5.1.3
RTCTMR_COMP
Default
Access
Description
FFFFFFFFh (RTC POR only)
R/W
RTC Time of Day Alarm [0..1] Compare Register
The compare value that causes the COMP{0,1}_FLAG to go active high when COMP{0,1}[31:0] matches TIMER_A[31:0].
10.3.5.1.4
RTCTMR_COMP0
Default
Access
Description
FFFFFFFFh (RTC POR only)
R/W
RTC Time of Day Alarm 0 Compare Register
This value is compared against the RTC timer value in the 4kHz clock domain. When a match occurs, the comp0_flag_a is set.
10.3.5.1.5
RTCTMR_COMP1
Default
Access
Description
FFFFFFFFh (RTC POR only)
R/W
RTC Time of Day Alarm 1 Compare Register
This value is compared against the RTC timer value in the 4kHz clock domain. When a match occurs, the comp1_flag_a is set.
10.3.5.1.6
RTCTMR_FLAGS
RTCTMR_FLAGS.comp0
Field
Bits
Default
Access
Description
comp0
0
0 (RTC POR only)
W1C
RTC Compare 0 Interrupt Status
Write 1 to clear.
Set to 1 by hardware when a match occurs between the RTC timer and the Compare Value 0.
Rev.1.3 April 2015
Maxim Integrated
Page 574