MAX32600 User’s Guide
System Clock, Timers/Counters, Watchdog Timers and Real Time Clock
10.3 Real Time Clock (RTC)
Field
Bits
Default
Access
Description
trim
4
0 (RTC POR only)
W1C
RTC Trim Interrupt Status
Write 1 to clear.
Set to 1 by hardware when a trim adjustment event occurs.
RTCTMR_FLAGS.comp0_flag_a
Field
Bits
Default
Access
Description
comp0_flag_a
8
0 (RTC POR only)
R/O
RTC Compare 0 4kHz Flag
Original event detection flag from 4kHz domain.
RTCTMR_FLAGS.comp1_flag_a
Field
Bits
Default
Access
Description
comp1_flag_a
9
0 (RTC POR only)
R/O
RTC Compare 1 4kHz Flag
Original event detection flag from 4kHz domain.
RTCTMR_FLAGS.prescl_flag_a
Field
Bits
Default
Access
Description
prescl_flag_a
10
0 (RTC POR only)
R/O
RTC Prescale Compare 4kHz Flag
Original event detection flag from 4kHz domain.
Rev.1.3 April 2015
Maxim Integrated
Page 576