MAX32600 User’s Guide
Analog Front End
8.4 DAC
Read-only.
0: FIFO is not in underflow condition 1: FIFO is in underflow condition
DACn_CTRL1_INT.out_done_ie
Field
Bits
Default
Access
Description
out_done_ie
16
0
R/W
DAC Output Done Interrupt Enable
Write 1 to enable interrupt source; 0 to disable.
DACn_CTRL1_INT.underflow_ie
Field
Bits
Default
Access
Description
underflow_ie
17
0
R/W
FIFO Underflow Interrupt Enable
Write 1 to enable interrupt source; 0 to disable.
DACn_CTRL1_INT.almost_empty_ie
Field
Bits
Default
Access
Description
almost_empty_ie
18
0
R/W
FIFO Almost Empty Interrupt Enable
Write 1 to enable interrupt source; 0 to disable.
DACn_CTRL1_INT.ahb_cg_disable
Field
Bits
Default
Access
Description
ahb_cg_disable
28
0
R/W
Local AHB dynamic clock gate disable
Rev.1.3 April 2015
Maxim Integrated
Page 469