MAX32600 User’s Guide
Analog Front End
8.2 AFE Reconfiguration Matrix
Field
Bits
Default
Access
Description
op_comp_a_nma
8
0
W1C
Op Amp Comparator A Non-Maskable Event
Flag
Set by hardware when the associated interrupt condition occurs. This is not a standard interrupt flag; instead it is a non-maskable, asynchronous output that goes
directly to the associated interrupt detector in the PMU. This will occur even if the AFE/ADC AMBA bus clock has been turned off for power savings reasons.
Write 1 to clear.
AFE_INTR.op_comp_b_nma
Field
Bits
Default
Access
Description
op_comp_b_nma
9
0
W1C
Op Amp Comparator B Non-Maskable Event
Flag
Set by hardware when the associated interrupt condition occurs. This is not a standard interrupt flag; instead it is a non-maskable, asynchronous output that goes
directly to the associated interrupt detector in the PMU. This will occur even if the AFE/ADC AMBA bus clock has been turned off for power savings reasons.
Write 1 to clear.
AFE_INTR.op_comp_c_nma
Field
Bits
Default
Access
Description
op_comp_c_nma
10
0
W1C
Op Amp Comparator C Non-Maskable Event
Flag
Set by hardware when the associated interrupt condition occurs. This is not a standard interrupt flag; instead it is a non-maskable, asynchronous output that goes
directly to the associated interrupt detector in the PMU. This will occur even if the AFE/ADC AMBA bus clock has been turned off for power savings reasons.
Write 1 to clear.
AFE_INTR.op_comp_d_nma