MAX32600 User’s Guide
Peripheral Management Unit (PMU)
6.4 Registers (PMU)
6.4.1.2
PMUn_CFG
PMUn_CFG.enable
Field
Bits
Default
Access
Description
enable
0
0
R/W
PMU Channel Enable
• 0: Disabled/stopped (this channel only)
• 1: Enabled/running (this channel only)
PMUn_CFG.ll_stopped
Field
Bits
Default
Access
Description
ll_stopped
2
1
R/W
Linked List Engine Status
• 0: Not stopped
• 1: Stopped
Set to 1 by hardware when the LL Engine executes a descriptor with the Stop bit set.
PMUn_CFG.manual
Field
Bits
Default
Access
Description
manual
3
0
R/W
Manual Mode Enable
• 0: Use linked list engine for PMU processing
• 1: Use descriptor registers only (loaded manually)
Rev.1.3 April 2015
Maxim Integrated