MAX32600 User’s Guide
System Configuration and Management
4.1 Power Ecosystem and Operating Modes
PWRMAN_INTEN.rtc_warning
Field
Bits
Default
Access
Description
rtc_warning
2
0
R/W
RTC Warning Monitor Int Enable
0:Int disabled; 1:Interrupt enabled for the associated SVM monitor event.
PWRMAN_INTEN.v3_3_reset
Field
Bits
Default
Access
Description
v3_3_reset
3
0
R/W
3.3V Reset Monitor Int Enable
0:Int disabled; 1:Interrupt enabled for the associated SVM monitor event.
PWRMAN_INTEN.vdda_warning
Field
Bits
Default
Access
Description
vdda_warning
4
0
R/W
VddA Warning Monitor Int Enable
0:Int disabled; 1:Interrupt enabled for the associated SVM monitor event.
4.1.12.1.4
PWRMAN_SVM_EVENTS
PWRMAN_SVM_EVENTS.v1_8_warning
Field
Bits
Default
Access
Description
v1_8_warning
0
n/a
R/O
1.8V Warning Monitor Event Input
Current state of the associated SVM event input.
Rev.1.3 April 2015
Maxim Integrated
Page 50