215015
130
Revision A
4.7
Calibrating the Swath Compressor Sensor
This topic only applies to machines equipped with a swath compressor. To calibrate the swath compressor sensor, follow
these steps:
1009099
CXXX
MXXX
WINDROWER SETUP?
NO/YES
A
B
Figure 4.92: CDM Programming Buttons
1.
Turn ignition key to RUN, or start the engine.
2.
Press PROGRAM (A) and SELECT (B) on cab display module
(CDM) to enter programming mode.
•
WINDROWER SETUP? is displayed on the upper line.
3.
Press SELECT (B) until CALIBRATE SENSORS? is displayed on
the upper line.
•
NO/YES is displayed on the lower line.
1030062
SWATH SENSOR CAL
SWATH UP TO START
C###
M###
B
A
Figure 4.93: Swath Compressor Sensor Calibration
4.
Press right arrow (A) to select YES. Press SELECT (B).
•
TO CALIBRATE SELECT is displayed in upper line.
5.
Press right arrow (A) to scroll through the choices until
SWATH COMPR HT is displayed on the lower line. Press
SELECT (B).
•
SWATH SENSOR CAL is displayed on the upper line.
•
SWATH UP TO START is displayed on the lower line.
1022623
A
B
Figure 4.94: Swath Compressor Controls
A - Lower Swath Compressor
B - Raise Swath Compressor
6.
Press and hold button (B) to raise the swath compressor.
•
CALIBRATING SWATH is displayed on the upper line.
•
FORM UP and flashing HOLD is displayed on the lower
line until the system has completed reading signal with
swath compressor fully raised.
•
SWATH FORM UP DONE (with buzzer) is displayed on
the lower line when complete.