CAUTION
Check to be sure all bystanders have cleared the area.
1009286
CXXX
MXXX
CALIBRATING FLOAT
FLOAT ( + ) HOLD
A
Figure 4.90: Positive Header Float Display
6.
Press and hold FLOAT + button (A) on the CDM.
•
CALIBRATING FLOAT is displayed on the upper line.
•
FLOAT ( + ) HOLD is displayed on the lower line.
NOTE:
The word HOLD will flash during calibration. FLOAT ( + )
DONE will display on the lower line once calibration is
complete.
7.
Release the FLOAT + button (A).
•
CALIBRATING FLOAT is displayed on the upper line.
•
FLOAT (
–
) HOLD is displayed on the lower line.
1009287
CXXX
MXXX
CALIBRATING FLOAT
FLOAT ( - ) HOLD
A
Figure 4.91: Negative Header Float Display
8.
Press and hold FLOAT
–
button (A) on CDM.
•
CALIBRATING FLOAT is displayed on the upper line.
•
FLOAT (
–
) HOLD is displayed on the lower line.
NOTE:
The word HOLD will flash during calibration. HDR FLOAT
COMPLETE will display on the lower line once calibration is
complete.
9.
Release FLOAT
–
button (A).
•
TO CALIBRATE SELECT is displayed on the upper line.
•
HEADER FLOAT is displayed on the lower line.
10. Press right arrow to select next header sensor calibration or STOP & EXIT. Press SELECT.
11. Press PROGRAM to exit programming mode.