Operating Modes
Version 6.03, May 2017
Page 34 of 192
Netto time
defines the integration period for the average netto vertical speed in seconds.
The default is 20 seconds.
The external switch wired to the vario unit has absolute priority and will override
all other switching methods.
5.1.4
Display
The display menu controls screen brightness. The main display unit has an ambient light
sensor which detects ambient light and automatically increases or reduces the brightness of
the screen.
If the
Automatic brightness
checkbox is selected, the instrument will automatically adjust
brightness according to current light conditions.
Minimum
and
Maximum brightness
items control value limits. Use time values to setup
how fast adaptation to brighter conditions or darker conditions will occur. Default values are
tuned to human eyes and do not require change.
Night mode brightness
defines maximum brightness when instrument is operating in
night mode. In night mode, brightness is reduced to very low value to reduce difference
between ambient light and device backlit.
If you want to set the brightness manually uncheck the
Automatic brightness
control and
set the brightness manually.
Change
Display orientation
if you would like to change the display unit screen orientation.
The main display unit will restart and start with new screen orientation.
Checking
Auto brightness on vario
while enable automatic regulation of brightness on
vario unit, if available. It this option is uncheck, vario unit will always run at full backlight.
It is recommended that the automatic brightness control is always enabled.
Reducing brightness will also reduce power consumption. See technical data for
more details (Chapter 2.1.9).