9. Object Dictionary
9-56
Monitoring (from 0x2600)
0x2600
Feedback Speed
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
INT - -
rpm
RO Yes -
No
This represents the current rotation speed of the motor.
0x2601
Command Speed
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
INT - -
rpm
RO Yes -
No
This represents the speed command input to the speed control loop of the drive.
0x2602
Following Error
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
DINT - -
pulse
RO Yes -
No
This represents the positional error of position control.
0x2603
Accumulated Operation Overload
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
INT - -
0.1%
RO No -
No
This represents the accumulated operation overload rate. When the value of the accumulated
operation overload rate reaches the overload warning level setting (0x2010), the operation overload
warning (W10) will occur; when it reaches 100%, the operation overload alarm (AL-21) will occur.
0x2604
Instantaneous Maximum Operation Overload
ALL
Variable
type
Setting range
Initial
value
Unit
Accessibility
PDO
assignment
Change
attribute
Storage
INT - -
0.1%
RO Yes -
No
This represents the maximum value of the operation overload rate output instantaneously from the
drive. This value can be initialized by the initialization of the instantaneous maximum operation
overload.
Summary of Contents for XDL-L7NH Series
Page 2: ......
Page 12: ......
Page 21: ...1 Product Configuration 1 9 1 3 2 Servo Motor Parts 80 Flange or below 130 Flange or higher ...
Page 43: ...2 Wiring and Connection 2 21 ...
Page 58: ......
Page 68: ......
Page 75: ...4 CiA402 Drive Profile 4 7 Internal Block Diagram of CSP Mode ...
Page 78: ...4 CiA402 Drive Profile 4 10 Internal Block Diagram of PP Mode ...
Page 86: ...4 CiA402 Drive Profile 4 18 Internal Block Diagram of PV Mode ...
Page 118: ...5 Drive Application Functions 5 10 ...
Page 148: ......
Page 283: ...10 Product Specifications 10 23 SGP Series APM SGP110G ...
Page 284: ...10 Product Specifications 10 24 SGP Series APM SGP150G ...
Page 288: ...10 Product Specifications 10 28 FGP Series APM FGP110G ...
Page 294: ...10 Product Specifications 10 34 XDL L7NHB150U Weight 15 5 kg including the cooling fan ...
Page 336: ...13 Appendix 13 20 5 Turn on the power again and verify if the firmware is updated ...
Page 346: ......