Page 62
Transport/Start up
Group 5
Release R1.06
JET3up
5.5.3.2
Mechanical installation
ATTENTION
For the mechanical installation of the shaft encoder you have to pay
attention in any case that the encoder is protected against axial and
radial strain during the mounting and the continuous operation. For
this a rubber gaiter or a plastic coupling is used.
If the conditions allow it, the shaft encoder can be also adapted to a production line
with a friction wheel.
ATTENTION
Risk of injury!
The shaft encoder has to be installed or mounted that no risks of
injury can occur!
5.5.4
Interface X4 - Digital inputs
19 inputs for special functions are available whereof the connections of 6 inputs can
be freely selected.
Plug assignment: Pin connection:
Pin Designation
Pin Designation
1
+Reset Counter
14 +24V
(1)
2
+Increment Counter
15 GND Reset Counter /
Increment Counter
3
+Jobselect 0
16 +Jobselect 1
4
+Jobselect 2
17 +Jobselect 3
5
+Jobselect 4
18 +Jobselect 5
6
+Jobselect 6
19 +Jobselect 7
7
+Jobselect 8
20 +Jobselect 9
8
GND Jobselect 0-9
21 GND Input 0-5
9
+Input 0
22 +Input 1
10 +Input 2
23 +Input 3
11 +Input 4
24 +Input 5
12 +Power ON
25 GND Power On
13 GND 24V
Summary of Contents for JET3 up
Page 1: ...Operating Manual V1 06 Please keep for future reference ...
Page 2: ......
Page 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Page 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Page 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Page 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Page 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Page 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...