Page 274
Job Editor
Group 8
Release R1.06
JET3up
8.5.2.7
Drop flight time
With this parameter the timing for the drop charging is adjusted. The input
dimension is µsec.
The current value set is displayed in the input field.
The parameter defines the time by which the ink drops are charged
earlier.
An
earlier charging of the ink drops brings some advantages for the positioning of the
drops at varying printing speeds.
With the drop flight time setting drop positioning issues caused by highly varying
printing speeds can be compensated to a certain degree.
For this a
<PrintGo delay>
setting
> 0
is required! The
<PrintGo delay>
is
necessary as a kind of buffer for the
<Drop-Flighttime>
set.
This function is only necessary if the printing speed varies in a wide range.
Figure 151 Setting of drop flight time
Drop Flighttime
compensation
The charging of the ink drops starts earlier
(blue dotted line).
The drop flight time compensation can be used for the
adjustment of the printing position at highly varying printing
speeds.
8.5.2.8
PrintStop reaction
A
<PrintStop>
can be processed in two ways:
1.
The current printout is finished when
<PrintStop>
occurs.
2.
The current printout stops immediately with the
<PrintStop>
. Parts
of the current print job may not be printed.
Immediate
<PrintStop>
not activated
Immediate
<PrintStop>
activated
PrintStart
PrintGo
delay
PrintGo
signal
Summary of Contents for JET3 up
Page 1: ...Operating Manual V1 06 Please keep for future reference ...
Page 2: ......
Page 18: ...Page 16 Introduction Group 1 Release R1 06 JET3up ...
Page 31: ...Group 2 Safety Page 29 JET3up Release R1 06 ...
Page 37: ...Group 3 Accident prevention Page 35 JET3up Release R1 06 ...
Page 42: ...Page 40 Accident prevention Group 4 Release R1 06 JET3up ...
Page 396: ...Page 394 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 2 Print head SK 6 ...
Page 398: ...Page 396 Appendix List of illustrations Group 12 Release R1 06 JET3up 12 4 4 Cabinet LJ ...